Configuration Settings Function Factory User Selectable Description Default Choices High Bypass 100V Models: 100V 110-120V Maximum voltage that the UPS will pass to Points 110V • 107V • 127V connected equipment during internal bypass 120V Models: • 110V • 130V operation. 133V • 113V • 133V • 116V • 136V • 119V • 139V • 122V • 142V • 125V • 145V • 128V • 148V Low Bypass 100V Models: 100V 110-120V Minimum voltage that the UPS will pass to Points 78V • 78V • 86V connected equipment during internal bypass 120V Models: • 80V • 88V operation. Targus Usb To Serial Software. 86V • 82V • 90V • 84V • 92V • 86V • 94V • 88V • 96V • 90V • 98V • 92V • 100V Output Frequency Automatic Automatic Sets the allowable UPS output frequency.

Apc Ups 3000 XlDownload Apc Surta 3000 Xl Manual Software

50 ± 3 Hz or 50 ± 3 Hz or Whenever possible, the output frequency tracks 60 ± 3 Hz 50 ± 0.1 Hz the input frequency. 60 ± 3 Hz or 60 ± 0.1 Hz Number of Battery 1 Number of connected Defines the number of connected battery packs Packs battery packs for proper run time prediction. 1 = internal battery module, 2 = one SURT192XLBP or SURT192XLBPJ, 3 = two SURT192XLBP or SURT192XLBPJ, etc.

Max All Skills Cheat Sims 2 Pc. Be Apc Surta 3000 Xl Manual, filtered, compared. Download Power Supply User's Manual of APC Smart UPS SURTA3000XL for free. APC Smart UPS SURTA3000XL Manual 1. APC; Smart Series; SURTA Series; SURTA 3000 XL; SURTA 3000 XL. Product Downloads. Spec Sheet File (Do Not Use): Download. Login to Order. Preview APC Power Supply Smart UPS SURTA3000XL User's Manual Page 5 Online and Download PDF Manuals & Instructions for FREE from Manualagent.com. APC SMART-UPS RT 3000VA Brazil 120V. Includes CD with software, Smart UPS signalling RS-232 cable, User Manual.

Storage, Maintenance, Transport, and Service Storage, Maintenance, Transport, and Service Storage Store the UPS covered in a cool, dry location with the battery(s) fully charged. At 5° to 113° F (–15°to 45° C), charge the UPS battery every six months. To Install a Replacement Battery This UPS has an easy-to-replace, hot-swappablebattery module. Replacement is a safe procedure, isolated from electrical hazards. You may leave the UPS and connected equipment on during the replacement procedure.

See your dealer or contact APC at the Web site, www.apc.com for information on replacement battery modules. The battery replacement procedure must include replacing all battery modules in the UPS and connected external battery pack(s). Remove all battery modules in the UPS. Remove the front bezel and screws. Pull down the battery cover and disconnect the top battery. Once the batteries are disconnected, the connected equipment is not protected from power outages.